PROBLEM:
Gui is throwing out an error causing a Lock-up.
Checking the validity of the license:
You can see that the license is still valid:
asmonitor /opt/plugins/check_op5_license -T d -w 30 -c 15
0 year(s) 2 month(s) 29 day(s) left|'left'=90;@30;@15
P.S For other process of looking into the license validity:
OP5 Monitor - How can I see what my ITRS OP5 Monitor License contains or how long it is valid? – Support - ITRS Group
SOLUTION:
Restart php-fpm service.
# systemctl restart php-fpm
This would fix the issue in most cases. If problem persists, contact ITRS support. A new license file may be needed.