Related to:
If there are more than one snooze command is issued on an item, which unsnooze command will take precedence?
Possible solution(s):
Whichever condition takes place first will take precedence.
Example 1:
At 0800, the following commands were issued against the same data item:
Snooze For Time Period - 10 hours
Snooze For Time Period - 5 hours
Then the data item will be unsnoozed at 1300.
Example 2:
At 0800, the following commands were issued against the same data item:
Snooze For Time Period - 1 hour
Snooze Until Severity changes..
The data item will be unsnoozed once the severity changes anytime between 0800 and 0900. Otherwise, the data item will be unsnoozed at 0900.
If you need further help:
- Please contact our support team via the chat service box on any of our websites or raise a support request.
- Make sure you provide us with:
- Background of the issue or request.
- Use cases, requirements, business impact, etc.
- Encountered error messages.
- Log files or diagnostic files.
- Screenshots.
- And other important information relevant to your inquiry.